[HTML][HTML] Performance assessment of the 2 γpositronium imaging with the total-body PET scanners

P Moskal, D Kisielewska, RY Shopa… - EJNMMI …, 2020 - ejnmmiphys.springeropen.com
… of the scanner was varied between 10 cm and 200 cm. … , 5×10 6 events with the emission
of prompt gamma from 44 Sc … are expected for LYSO-based total-body PET. These numbers …

[HTML][HTML] State of the art in total body PET

S Vandenberghe, P Moskal, JS Karp - EJNMMI physics, 2020 - Springer
… the direction of gamma photons emitted from the source and the … by a set of closely placed
point sources, and sensitivity can … length for a point source, short object 10 cm, a 100-cm-long …

Simulating NEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators

P Moskal, P Kowalski, RY Shopa… - Physics in Medicine …, 2021 - iopscience.iop.org
… , for 140 cm long tomograph and the point source placed in … locations (x = 1 cm, 10 cm and
20 cm) and two axial—at the … source of back-to-back gamma photons with length of 70 cm was …

[HTML][HTML] Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation …

L Labate, D Palla, D Panetta, F Avella, F Baffigi… - Scientific reports, 2020 - nature.com
… depths in the range from 5 to 10 cm with mm resolution. The … passive collimator, placed at
about 38 cm downstream of the … ) so as to reduce the X/\(\gamma\)-ray photons produced via …

Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157

CMC Ma, IJ Chetty, J Deng, B Faddegon… - Medical …, 2020 - Wiley Online Library
… MC-based dose calculations for radiation therapy with gamma … those of the electron beam
at or near the exit window. These … of 10 cm in water for a 10 cm × 10 cm field defined at 100 cm

[PDF][PDF] Determination of shielding effectiveness of some selected materials available in lesotho using MCNP code

MD Sello - 2019 - researchgate.net
… places, it is most effective in neutron shielding relative to gamma and x-rays … source results
were found to fall in between point and plaque sources giving HVLs 20 cm for wood, 10 cm

Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy

W Deng, JE Younkin, K Souris, S Huang… - Medical …, 2020 - Wiley Online Library
… -based dose calculation code with MPI capability, web-based second … with PSQA
measurements using gamma index analysis with … , we observed a discrepancy near the Bragg …

[HTML][HTML] Advanced Monte Carlo simulations of emission tomography imaging systems with GATE

D Sarrut, M Bała, M Bardiès, J Bert… - Physics in Medicine …, 2021 - iopscience.iop.org
… The source is a monoenergetic 511 keV gamma point source… cone surface where the
source is located, a dedicated … , 1 m and 2 m long systems, covering the whole human body

Mitigating COVID-19 infection disease transmission in indoor environment using physical barriers

C Ren, C Xi, J Wang, Z Feng, F Nasiri, SJ Cao… - Sustainable cities and …, 2021 - Elsevier
… The staff member is seated assuming a body size of 0.4 m (… above 40 cm, the airflow from
the pollution source located at B … for a pollution source close to outlet (ie, pollutant source at B …

[HTML][HTML] Neuropharmacological and Antidiabetic Potential of Lannea coromandelica (Houtt.) Merr. Leaves Extract: An Experimental Analysis

F Islam, S Mitra, MH Nafady, MT Rahman… - … and Alternative …, 2022 - hindawi.com
… e arms were joined with a central square measuring 10 cm by 10 cm to … e doses of 200 and
400 mg/kg body weight were chosen … It also had a preventive role when provided before the …